Specification of ground level along pipeline axis (Input Table)
Data description/conditions:
Identifier: (toggleable)
Identification name of data reference point
Required
GROUND1:
Z-coordinate of ground level just before and at x-p ref. point
None / Required
(The value given for GROUND1 on the first data table line is valid for every value of X less than X-P(1))
UNCV1:
Uncertainty value for depth of pipeline axis below ground level
≥ 0.
[Default: 0.]
GROUND2:
Z-coordinate of ground level just after x-p reference point
None / Undefined
(The value given for GROUND2 on the last data table line (n) is valid for every value of X greater than X-P(n). If GROUND2 = Undefined it is assumed GROUND2 = GROUND1)
UNCV2:
Uncertainty value for depth of pipeline axis below ground level
≥ 0. / Undefined
[Default: 0.]
(The value given for UNCV2 on the last data table line(n) is valid for every value of X greater than X-P(n). If UNCV2 = Undefined it is assumed that UNCV2=UNCV1)
H200131 (last modified: Jan 25, 2026