Specification of maximum bearing capacity of sub-soil along pipeline axis (Input Table)
Data description/conditions:
Identifier: (toggleable)
Identification name of data reference point
Required
RVS1:
Maximum bearing capacity just before and at data reference point
≥ 0.
RVS2:
Maximum bearing capacity just after data reference point
≥ 0. / Undefined
(If RVS2=UNDEFINED it is assumed RVS2 = RVS1)
UNCF-L:
Uncertainty factor resulting in lower soil parameter rvs
≥ 1. / Undefined if UNCF-H is specified
[Default: 2.0]
(If UNCF-L = UNDEFINED it is assumed that UNCF-L = UNCF-H. UNCF-L is used when the uncertainty in table UNCER is set to Low)
UNCF-H:
Uncertainty factor resulting in higher soil parameter rvs
≥ 1. / Undefined if UNCF-L is specified
[Default: 2.0]
(If UNCF-H = UNDEFINED it is assumed UNCF-H = UNCF-L. UNCF-H is used when the uncertainty in table UNCER is set to High)
VARAR:
Half band width accuracy allowance percentage for soil parameter
> 0. and < 50. / Undefined if RVS1=RVS2=0.
[Default: 5.]
H320151 (last modified: Nov 15, 2024