List of elements with primary membrane stresses (Output Table)
Data description/Result options:
ELEM:
Element number
(NO)SOILNB:
Indication whether element is to be characterised as a primary membrane stress element in case of above ground pipeline (section) or when SOILNB only exists
SOILNB+TOPLOAD:
Indication whether element is to be characterised as primary membrane stress element when SOILNB and TOPLOAD exist
Possible indications:
- empty (blank) |
|
No primary membrane stress element |
- Primary (free) |
|
Primary membrane stress element with gap or above ground |
- Primary (in soil) |
|
Primary membrane stress element below ground |
- Primary (support) |
|
Primary membrane stress element next to a support |
- Non-Primary (elastic) |
|
Elastic bend element (is always a non-primary membrane stress element) |
- Weak |
|
Weak element |
- Joint |
|
Joint element |
The length of the pipe span for the combination of SOILNB and TOPLOAD can differ from the one for SOILNB only, because a part of the span at start and/or end may disappear due to additional loading by TOPLOAD.
H610571, last changed: 2009-07-17
See also: