List of tee stress intensification factors (Output Table)
Data description/Result options:
CONNAME:
Name of tee
TYPE:
Type of tee (1)
T-UP:
Nominal wall thickness of run or matching pipe (1)
R2-MP:
Mean radius of matching run pipe (1)
TE:
Thickness of pad or saddle (1)
(Only provided in case of REINFORCED type of tee)
R0:
Radius of curvature of external contoured portion of outlet (1)
(Only provided in case of WELDING, WELDED-IN or EXTRUDED tee)
H:
Flexibility characteristic (1)
SIX-OP:
Stress intensification factor in axial direction due to bending out of plane of tee (1)
SIX-IP:
Stress intensification factor in axial direction due to bending in plane of tee (1)
The number of rows is the number of tees specified.
See table H.3 from NEN-EN 13480-3 and the notes from table E1 of Appendix E of ASME B31.8.
H500581 (last modified: Jan 14, 2025)
See also: