Perform cross-section calculations and checks according to ASME B31.8
Function ready condition: - if input data table SECT318 is tested.
Function error condition: 2 error conditions, 4 warning conditions, 4 messages
Data missing, recalculate from DF5.
Internal data calculated in design function 5 can not be found. Please set back design function 5 and recalculate from there.
(This error can occur after updating a project from a previous version of the program. If only design function 6 is recalculated after the update, not all required data might be present.)
Num of cross-sec. limited to 'number'
The number of elements mentioned in the SECT318 table is limited to 'number', even if individual elements are mentioned more than once in the table (i.e. the number of actual elements to be calculated may be less than the limit).
Please note that the limit for the educational version is 50 elements.
Ovalisation is 'value' % of diameter
The ovalisation of an element exceeds 10% of the diameter.
(An ovalisation exceeding 10% is considered to be very large.)
Elements with and without topload
In table SECTION some elements have a TOPLOAD 'Yes' indicator, some a 'No' indicator.
(Having toploads assigned in table TOPLOAD it is advised to have the same indicator on each input line. Especially when the Ovalising Section Model combined with the Allowed Ovalisation Redistribution is selected in design function 1. When all input lines have a 'Yes' indicator (also in those pipeline parts where no topload is present) a correct redistribution will be performed.
'number1' out of 'number2' elm. not calc ('number')
Not all elements (number1) out of the total amount of elements (number2) are calculated. Between brackets the first not calculated element.
Calculated stress > allowable stress
At least one of the calculated check stresses in table SMAX318 exceeds the allowable stress elaborated in output table CSGENB.
Weak element(s) not calculated
Only WEAK elements have been specified in (a row of) table SECT318.
No elements calculated
Only WEAK elements have been specified in table SECT318.
All elements already calculated
All pipeline cross-sections specified in table SECT318 are already calculated including the detailed stresses of the last specified element in table SECT318.
Topload = 0.
The TOPLOAD indicator in table SECT318 is YES and (the TOPLOAD-value =0. and the Loading Redistribution option is OFF or no table TOPLOAD exists).
•in output table CSLOAD the relevant TOPLOAD-value will become indicated .0 or UNDEFINED if no table TOPLOAD exists.
(This message is given to indicate that the TOPLOAD specified is zero over (parts of) the pipeline. this may be the real situation, but it is also possible that input of the TOPLOAD table has been omitted erroneously.)